LSPOne - Microfluidic Spritzenpumpensystem
Produktbild kann vom Original abweichen
LSPOne - Microfluidic Spritzenpumpensystem
LSPOne - Microfluidic Spritzenpumpensystem
LSPOne - Microfluidic Spritzenpumpensystem
Datenblätter:

P100-L LSPOne - Microfluidic Spritzenpumpensystem

Lieferumfang: Netzkabel, Mini-USB, Software, Spritzenwechsel-Tool
ca. 2-3 Wochen
Artikelnr.
P100-L
$ 4.314,76

Sie benötigen größere Mengen? Gerne erstellen wir Ihnen ein individuelles Angebot. Angebot jetzt anfragen

Syringe configurations:

Reference Volume Plunger materials Min. flow rate Max. flow rate Min dosing volume
S-25-P 25 μL PTFE 0.25 μL/min 750 μL/min 0.05 μL
S-50-P 50 μL PTFE 0.5 μL/min 1'500 μL/min 0.1 μL
S-100-P or S-100-U 100 μL PTFE or UHMW-PE 1 μL/min 3'000 μL/min 0.2 μL
S-250-P 250 μL PTFE 2.5 μL/min 8'000 μL/min 0.5 μL
S-500-P or S-500-U 500 μL PTFE or UHMW-PE 5 μL/min 15'000 μL/min 1 μL
S-1000-P/td> 1000 μL PTFE 10 μL/min 30'000 μL/min 2 μL

Valve configurations:

Reference Configuration Wetted materials Internal vol. Carryover vol. Channel ø Max. pressure
V-D-2-6-050-C-P 6-ports ultra-low carryover volume PCTFE,PTFE 5.2 μL 1.5 μL 0.5 mm 7 bars
V-D-1-6-050-C-P 6-ports low carryover volume PCTFE,PTFE 3.5 μL 2.6 μL 0.5 mm 7 bars
V-D-1-8-050-C-P 8-ports low carryover volume PCTFE,PTFE 3.5 μL 2.6 μL 0.5 mm 7 bars
V-D-1-8-100-C-U 8-ports low carryover volume PCTFE,UHMW-PE 18.1 μL 11 μL 1 mm 7 bars
V-D-1-10-050-C-U 10-ports low carryover volume PCTFE,UHMW-PE 4.5 μL 2.8 μL 0.5 mm 7 bars
V-D-1-10-100-C-U 10-ports low carryover volume PCTFE,UHMW-PE 18.1 μL 11 μL 1 mm 7 bars
V-D-1-12-050-C-U 12-ports low carryover volume PCTFE,UHMW-PE 4.5 μL 2.8 μL 0.5 mm 7 bars

Specifications:

Operating temperature 5-40°C (41-104°F)
Operating humidity 20-80%, non-condensing
Max. pressure 7 bars (102 psi)
Wetted materials PTFE or UHMW-PE, PCTFE and borosilicate glass
Dead volume None
Carryover volume Down to 1.5 μL (configuration dependent)
Plunger travel 30 mm with 96'000 micro-steps for nearly pulseless flow
Plunger resolution Selectable 3'000 steps (standard) / 24'000 steps (high)
Plunger drive Screw drive with linear encoder for step loss detection
Valves configuration Zero dead-volume multi-port distribution with angular encoder
Tube port fittings Standard 1/4-28 UNF, flat-bottom
Cross-contamination Typically from 1/100 zo 1/1000 per cleaning cycle
Accuracy < 1% deviation from expected value at full stroke
Electrical interface USB mini, 9-pin D-Sub (other upon request)
Communication type Serial (other upon request)
Power 18-24 VDC, 2.2 A peak, 40 W
Time for full stroke 2 - 3'000 seconds
Dimensions 245 x 143 x 85 mm
Weight 2.2 kg
Graphical user interface MS Windows 7 and later, MAC OSX
Certifications CE and CB certified